CHARACTERISTICS: Wind direction sensor is characterized by good linearity, high accuracy, no dead spot, no fear of strike, and easy observation, more stable and use. Users can know the wind direction through the sensor and make corresponding decisions and countermeasures.
ALL AROUND: The internal angle sensor is able to realize all round 360 degrees wind direction monitoring. Users can get a full range of wind direction information, ensuring the comprehensiveness and accuracy of the data.
PREMIUM MATERIAL: Made of low inertia ABS material with good dynamic characteristics. The premium material made it has stable performance and lasting reliability, and well in various environments.
Item Type: Wind Direction Sensor
Material: ABS
Weight: Approx. 385g Celsius 13.6oz
Product Size: Approx. 223x190x70mm Celsius 8.8x7.5x2.8in
Supply Voltage: 9-30V
Output: 4-20mA
Extension Wire Length At Connection: 0.8m Celsius 2.6ft
Accuracy: Directional: +Celsius- 3 degrees
Resolution: Directional: 1 degrees
Starting Wind Speed: less than 0.8mCelsiuss
Maximum Power Consumption: 0.48W
Load Capacity: 12V power supply, current type output impedance less than 350 Ohm , 24V power supply, current type output impedance less than 900 Ohm , voltage type output impedance more than 1K Ohm
Operating Environment: Temperature -35 celsius -60 celsius
Humidity: less than 100% without condensation
Prevention Grade: IP64
Cable Grade: Rated Voltage: 300V 80 degrees C
Mounting Hole Diameter: 3.2mm Celsius 0.13in
Aerial Plug Diameter: 15mm Celsius 0.59in (It is recommended to reserve 25mm Celsius 0.98in for easy wiring, wiring first, then install the fixed sensor)
Calculation :
4-20mA: F=(I-4)Celsius16x359
Attention:
F: Indicates the wind direction angle value, unit: degrees .
I: Sensor output current value, mA
Wiring Methods (Wire )
Wire color
Output signal (current)
Red Power positive
Black Power negative
Yellow Signal
Troubleshooting :
1. The wind blades do not rotate properly, and the hysteresis is big. There are foreign objects or jammed in the bearing due to term use. Please send the sensor back to the company for processing.
2. Analog signal meter display value is not correct. Possible wiring problems or communication serial port failure caused by the inability to obtain the correct data. Please check whether the wiring is correct and firm, whether the serial port is occupied, and whether the serial port setting is correct.
3. If it is not the reasons, please contact customer service.